Bypass TT rail 25 AC 
Order Number: ASATT25RA__BP print data sheet of product

order number

description

weight

ASATT25RA66BP

TT 25 rail 230/400V 0,37kW with internal bypass (motor according EU standards)

32,5 kg

ASATT25RA66BP

TT 25 rail 230/460V 0.50 HP with internal bypass (motor according US standards)

71.65 lbs

ASATT25RA47BP

TT 25 rail 230/400V 0,75kW with internal bypass (motor according EU standards)

41,6 kg

ASATT25RA46BP

TT 25 rail 230/460V 0.75HP with internal bypass (motor according US standards)

71.21 lbs

 

principle:

By integrating a bypass system in an asa radiator, it is possible

to avoid overstressing the cooler at cold start conditions

(when the oil is extremely viscous)

This mode of construction also reduces high oil flows through

the radiator, which can occur when for example hydraulic

cylinders are used.

valve:

- spring loaded valve

- opening pressure: 2bar (30 PSI)

- dimension: BSP ½

 

 

Cooling Performance* Pressure Drop
DRAWING: