Bypass ASA 0467 AC 
Order Number: ASA0467AA__BP

order number

description

ASA0467AA66BP

ASA 0467 230/400V (50Hz) 0,37kW with internal bypass (motor according to EU standard)

ASA0467AA47BP

ASA 0467 230/400V (50Hz) 0,75kW with internal bypass (motor according to EU standard)

ASA0467AA4ABP

ASA 0467 230/400V (50Hz) 2,20kW with internal bypass (motor according to EU standard)

ASA0467AA66BP

ASA 0467 230/460V (60Hz) 0.5HP with internal bypass (motor according to US standard)

ASA0467AA48BP

ASA 0467 230/460V (60Hz) 1.5HP with internal bypass (motor according to US standard)

ASA0467AA4BBP

ASA 0467 230/460V (60Hz) 4HP with internal bypass (motor according to US standard)

 

principle:

By integrating a bypass system in an asa radiator, it is possible to avoid overstressing the cooler at cold start conditions(when the oil is extremely viscous)

This mode of construction also reduces high oil flows through the radiator, which can occur when for example hydraulic cylinders are used.

valve:

- spring loaded valve

- opening pressure: 2bar (30 PSI)

- dimension: BSP 1“

DRAWING:
Print Page