Bypass ASA 0567 AC 
Order Number: ASA0567AA__BP print data sheet of product

order number

description

ASA0567AA66BP

ASA 0567 230/400V (50Hz) 0,37kW with internal bypass (motor according to EU standard)

ASA0567AA47BP

ASA 0567 230/400V (50Hz) 0,75kW with internal bypass (motor according to EU standard)

ASA0567AA4ABP

ASA 0567 230/400V (50Hz) 2,20kW with internal bypass (motor according to EU standard)

ASA0567AA66BP

ASA 0567 230/460V (60Hz) 0.5HP with internal bypass (motor according to US standard)

ASA0567AA48BP

ASA 0567 230/460V (60Hz) 1.5HP with internal bypass (motor according to US standard)

ASA0567AA4BBP

ASA 0567 230/460V (60Hz) 4HP with internal bypass (motor according to US standard)

 

principle:

By integrating a bypass system in an asa radiator, it is possible to avoid overstressing the cooler at cold start conditions(when the oil is extremely viscous)

This mode of construction also reduces high oil flows through the radiator, which can occur when for example hydraulic cylinders are used.

valve:

- spring loaded valve

- opening pressure: 2bar (30 PSI)

- dimension: BSP 1“

Cooling Performance* Pressure Drop
DRAWING:
Print Page